Camera Zoom.
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
Camera Number | id | - | uint8_t | The identification number of the destination camera. | Same as field type |
Absolute Zoom Level | zoom | - | uint8_t | Absolute zoom level. | Same as field type |
Action | action | Enumerated (Enum Action) | uint8_t | The zoom action to perform. | Same as field type |
The zoom action to perform.
Value | Name | Abbreviation | Description |
---|---|---|---|
0 | Reset Zoom | ZOOM_RESET | - |
1 | Zoom In | ZOOM_IN | - |
2 | Zoom Out | ZOOM_OUT | - |
3 | Stop Zooming | ZOOM_STOP | - |
Actuate directly on a thruster.
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
Thruster Number | id | - | uint8_t | The identification number of the destination thruster. | Same as field type |
Actuation Value | value | - | fp32_t | Actuation magnitude. | min=-1, max=1 |
Set the position of a servo.
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
Identifier | id | - | uint8_t | The identification number of the destination servo. | Same as field type |
Position | value | rad | fp32_t | Actuation magnitude. | min=-1.5707963267948966, max=1.5707963267948966 |
Set the deflection angle of a control surface.
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
Identifier | id | - | uint8_t | The identification number of the destination control surface. | Same as field type |
Angle | angle | rad | fp32_t | Actuation magnitude. | Same as field type |
This message is used as query to request for the possible remote actions (operation=QUERY and the list is empty in this case). The vehicle responds using the same message type returning the tuplelist with the pairs: Action,Type (operation=REPORT). The type of action can be Axis, Hat or Button.
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
operation | op | Enumerated (Enum operation) | uint8_t | Operation to perform. | Same as field type |
Actions | actions | TupleList | plaintext | Example: “Propulsion=Axis,PanTilt=Hat,Lights=Button” | Same as field type |
Operation to perform.
Value | Name | Abbreviation | Description |
---|---|---|---|
0 | Report | REPORT | - |
1 | Query | QUERY | - |
This message is used to send a periodic update of values for each remote action. If the action is not on the list the assumed value is 0.
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
Actions | actions | TupleList | plaintext | List of values for each remote action (e.g: “Propeller=0.6,PanTilt=0.75,Lights=1”). | Same as field type |
Event of a specific hardware button.
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
Button | button | - | uint8_t | Button identifier. | Same as field type |
Value | value | - | uint8_t | Value of the button. | Same as field type |
Control LCD.
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
Operation | op | Enumerated (Enum Operation) | uint8_t | The LCD action to perform | Same as field type |
Text | text | - | plaintext | Text to be written (if defined write operation). | Same as field type |
The LCD action to perform
Value | Name | Abbreviation | Description |
---|---|---|---|
0 | Turn off display | TURN_OFF | - |
1 | Turn on display | TURN_ON | - |
2 | Clear display | CLEAR | - |
3 | Write Line #0 | WRITE0 | - |
4 | Write Line #1 | WRITE1 | - |
This message allows controlling the system’s power lines.
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
Operation | op | Enumerated (Enum Operation) | uint8_t | Operation type. | Same as field type |
Time Remaining | time_remain | s | fp32_t | Time remaining to complete operation. | Same as field type |
Scheduled Time | sched_time | s | fp64_t | Scheduled time of operation. | Same as field type |
Operation type.
Value | Name | Abbreviation | Description |
---|---|---|---|
0 | Power Down | PWR_DOWN | Request the destination entity of this message to power down it’s devices immediately. If the destination entity is the special entity ‘0’ the whole system will power down. |
1 | Power Down in Progress | PWR_DOWN_IP | The latest power down request is in progress and the time remaining until power down is given in field ‘time_remain’. |
2 | Power Down Aborted | PWR_DOWN_ABORTED | The latest power down request was aborted. |
3 | Schedule Power Down | SCHED_PWR_DOWN | Request the destination entity of this message to power down it’s devices at the time given in the field ‘sched_time’. If the destination entity is the special entity ‘0’ the whole system will power down. |
4 | Power Up | PWR_UP | Request the destination entity of this message to power up it’s devices. |
5 | Power Up in Progress | PWR_UP_IP | The latest power up request is in progress. |
6 | Schedule Power Up | SCHED_PWR_UP | Request the destination entity of this message to power up it’s devices at the time given in the field ‘sched_time’. If the destination entity is the special entity ‘0’ the whole system will power up. |
This message allows controlling power channels.
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
Channel Name | name | - | plaintext | The name of the power channel. | Same as field type |
Operation | op | Enumerated (Enum Operation) | uint8_t | Operation to perform. | max=6 |
Scheduled Time | sched_time | s | fp64_t | Scheduled time of operation. | Same as field type |
Operation to perform.
Value | Name | Abbreviation | Description |
---|---|---|---|
0 | Turn Off | TURN_OFF | Turn off power channel specified in field ‘id’. |
1 | Turn On | TURN_ON | Turn on power channel specified in field ‘id’. |
2 | Toggle | TOGGLE | Toggle power channel specified in field ‘id’. |
3 | Schedule Turn On | SCHED_ON | Turn on power channel specified in field ‘id’ in ‘sched_time’ seconds. |
4 | Schedule Turn Off | SCHED_OFF | Turn off power channel specified in field ‘id’ in ‘sched_time’ seconds. |
5 | Reset Schedules | SCHED_RESET | Reset all scheduled operations for the channel specified in field ‘id’. |
6 | Save Current State | SAVE | Save the current state of the channel ‘id’ to persistent storage. |
7 | Restart | RESTART | Restart power channel specified in field ‘id’. |
Request the state of power channels.
This message has no fields.
Message conveying the state of a power channel.
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
Name | name | - | plaintext | Power Channel Name. | Same as field type |
State | state | Enumerated (Enum State) | uint8_t | State of the Power Channel. | Same as field type |
State of the Power Channel.
Value | Name | Abbreviation | Description |
---|---|---|---|
0 | Off | OFF | Power channel is off. |
1 | On | ON | Power channel is on. |
Brightness value of an LED (Light-Emitting Diode).
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
Name | name | - | plaintext | LED name. | Same as field type |
Value | value | - | uint8_t | Brightness value. | Same as field type |
Query the brightness of an LED (Light-Emitting Diode). The recipient of this message shall reply with ‘LedBrightness’.
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
Name | name | - | plaintext | LED name. | Same as field type |
Control the brightness of an LED (Light-Emitting Diode). The recipient of this message shall set the intensity of the LED to the desired ‘value’ and reply with ‘LedBrightness’.
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
Name | name | - | plaintext | LED name. | Same as field type |
Value | value | - | uint8_t | Desired brightness value. | Same as field type |
Set properties of a PWM signal channel.
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
Channel Identifier | id | - | uint8_t | PWM channel identifier. | Same as field type |
Period | period | µs | uint32_t | The total period of the PWM signal (sum of active and inactive time of the PWM). | Same as field type |
Duty Cycle | duty_cycle | µs | uint32_t | The active time of the PWM signal. The duty cycle value must be less or equal to the period. | Same as field type |
Properties of a PWM signal channel.
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
Channel Identifier | id | - | uint8_t | PWM channel identifier. | Same as field type |
Period | period | µs | uint32_t | The total period of the PWM signal (sum of active and inactive time of the PWM). | Same as field type |
Duty Cycle | duty_cycle | µs | uint32_t | The active time of the PWM signal. The duty cycle value is less or equal to the period. | Same as field type |
Current state of a GPIO.
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
Name | name | - | plaintext | GPIO Name. | Same as field type |
Value | value | - | uint8_t | Logical level of the GPIO. | Same as field type |
Request the state of a given GPIO. The receiving entity shall reply with a GpioState message.
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
Name | name | - | plaintext | GPIO Name. | Same as field type |
Set the state of a given GPIO. The receiving entity shall reply with a GpioState message.
Name | Abbreviation | Unit | Type | Description | Range |
---|---|---|---|---|---|
Name | name | - | plaintext | GPIO Name. | Same as field type |
Value | value | - | uint8_t | Logical level of the GPIO. | Same as field type |